Metric threads·M48×3
M48×3
Tap drill
45 mm

M48×3 thread — 45 mm tap drill, 44.319 mm minor diameter

Fine

M48×3 is a fine thread: 48 mm across with a 3 mm pitch. The bolt’s minor diameter is 44.319 mm, the tap drill 45 mm and the stress area 1603.54 mm².

Outside diameter
48 mm
Pitch
3 mm (Fine)
Pitch diameter
46.051 mm
Minor diameter (bolt)
44.319 mm
Minor diameter (nut)
44.752 mm
Thread height
1.84 mm
Stress area
1603.54 mm²
Threads per inch
8.47

The thread is a 60° triangle

ISO defines the thread profile as an equilateral 60° triangle. Its height H is 0.866 × pitch, and every other diameter is that triangle cut back by a fixed fraction of H.

H = 0.866 × 3 = 2.598 mm · 46.051 = 48 − 0.75 × 2.598

The stress area sets the strength

A bolt’s load capacity is worked out from this area, not from the outside diameter. It is the area of a circle whose diameter is the average of the pitch and minor diameters.

Other pitches at this diameter

A tighter pitch cuts shallower, leaving a thicker core. That is why fine threads suit thin walls and places that vibrate.

One size up and down

The 35 coarse threads

Each diameter has one default pitch. When someone just says “M8”, they mean M8×1.25.

How to read this

  • The number after M is the outside diameter in mm; the number after × is the pitch in mm.
  • H = 0.866 × pitch. The pitch diameter is d − 0.75H, the nut’s minor diameter d − 1.25H.
  • Take the tap drill as outside diameter minus pitch, then pick the nearest drill you own.
  • Load capacity comes from the stress area, not from the outside diameter.

Frequently asked questions

Q. What drill do I need to tap M48×3?

45 mm — the 48 mm outside diameter minus the 3 mm pitch. Use the nearest drill you have.

Q. What is the minor diameter of M48×3?

44.319 mm on the bolt and 44.752 mm in the nut, with the pitch diameter between them at 46.051 mm.

Q. Is it a coarse or a fine thread?

Fine. There is a coarse pitch for this diameter too, so the pitch must always be written out.

Q. How much load does it take?

Its stress area is 1603.54 mm². Multiply that by the bolt’s strength grade to get the load it carries.