Appliance current·space heater
space heater · 2200W
22A
Japan 100 V · 15 A

space heater, 2200 W — 22 A on a 100 V / 15 A circuit

2200 W divided by 100 V is 22 A. This circuit allows 12 A continuously, so 0 of them can run together.

Too much for this circuit alone

Plug it straight into the wall

Power draw
2200 W
Voltage
100 V
Breaker
15 A
Current that flows
22 A
Limit for continuous use
12 A
How many fit at once
0
Wire it needs
4mm²
Two hours a day, per month
132 kWh

Continuous loads get eight tenths

A breaker does not trip the instant you reach its rating — it holds for a long while first, and the wire warms up in the meantime. So a load running more than three hours is planned to eight tenths of the breaker. On a 16 A breaker that is 12.8 A.

Nearby cells

Same appliance, other circuits

Same circuit, other appliances

How to read this

  • Current is the power draw divided by the voltage — a different country gives a different answer.
  • The number that fits at once is eight tenths of the breaker divided by that current.
  • A power strip stops at 15 A. A bigger breaker does not help; the strip is the ceiling.
  • The wire gauge is taken straight from the wire pages.

Frequently asked questions

Q. How many amps does a space heater draw?

2200 W over 100 V is 22 A.

Q. How many fit on this circuit?

0. Eight tenths of the 15 A breaker is 12 A, divided by 22 A.

Q. Is a power strip fine?

No. It passes 15 A, so plug it straight into the wall.

Q. What wire does it need?

4mm² carries this current comfortably. Two hours a day comes to 132 kWh a month.