Insulation·rigid polyurethane 100mm
rigid polyurethane · 100mm
R 4.35
U 0.221 W/m²·K

rigid polyurethane, 100 mm — R 4.35

100 mm divided by a conductivity of 0.023 gives an R-value of 4.35. The U-value is 0.221, so a square metre leaks 4.43 W across a 20-degree difference.

Standards it meets

  • loose standard 0.30
Material
rigid polyurethane
Thickness
100 mm
Thermal conductivity
0.023 W/m·K
Thermal resistance
4.35 m²·K/W
U-value
0.221 W/m²·K
Heat lost per square metre
4.43 W
As concrete
6.96 m

Thickness for the same performance

This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.

  • vacuum panel30 mm
  • phenolic foam87 mm
  • extruded polystyrene122 mm
  • graphite EPS135 mm
  • white EPS157 mm
  • glass wool161 mm
  • mineral wool174 mm
  • cellulose183 mm
  • timber565 mm
  • plasterboard783 mm
  • concrete6957 mm

Nearby cells

Same material, other thicknesses

Same thickness, other materials

How to read this

  • Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
  • The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
  • Resistances add across layers, so a whole wall is the sum of its parts.
  • Conductivity varies by product; the values here are typical for the material.

Frequently asked questions

Q. What is the R-value of 100 mm of rigid polyurethane?

4.35 — 100 mm in metres divided by a conductivity of 0.023.

Q. And the U-value?

0.221. That is 4.52 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 4.43 W across 20 degrees.

Q. How much concrete would match it?

6.96 metres.

Q. Which standards does it meet?

At 0.221 it clears 1 of them.