Insulation·timber 300mm
timber · 300mm
R 2.31
U 0.404 W/m²·K

timber, 300 mm — R 2.31

300 mm divided by a conductivity of 0.13 gives an R-value of 2.31. The U-value is 0.404, so a square metre leaks 8.07 W across a 20-degree difference.

Standards it meets

Not up to any of them yet

Material
timber
Thickness
300 mm
Thermal conductivity
0.13 W/m·K
Thermal resistance
2.31 m²·K/W
U-value
0.404 W/m²·K
Heat lost per square metre
8.07 W
As concrete
3.69 m

Thickness for the same performance

This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.

  • vacuum panel16 mm
  • phenolic foam46 mm
  • rigid polyurethane53 mm
  • extruded polystyrene65 mm
  • graphite EPS72 mm
  • white EPS83 mm
  • glass wool85 mm
  • mineral wool92 mm
  • cellulose97 mm
  • plasterboard415 mm
  • concrete3692 mm

Nearby cells

Same material, other thicknesses

Same thickness, other materials

How to read this

  • Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
  • The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
  • Resistances add across layers, so a whole wall is the sum of its parts.
  • Conductivity varies by product; the values here are typical for the material.

Frequently asked questions

Q. What is the R-value of 300 mm of timber?

2.31 — 300 mm in metres divided by a conductivity of 0.13.

Q. And the U-value?

0.404. That is 2.48 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 8.07 W across 20 degrees.

Q. How much concrete would match it?

3.69 metres.

Q. Which standards does it meet?

At 0.404 it does not clear any of them yet.