Room lighting·50operating table
50㎡ · operating table
75000
lm · 1500 lux

50 m² operating table — 75000 lumens

A room at 1500 lux needs 75000 lumens. That is 750 watts of LED, or 94 bulbs of 800 lumens.

Watts are not brightness

Equal lumens mean equal brightness; what changes is the electricity. An LED makes 100 lumens per watt, a filament 13 — nearly eight times apart. The monthly figure below assumes five hours a day for thirty days.

  • LED100 lm/W750 W
  • fluorescent60 lm/W1250 W
  • halogen20 lm/W3750 W
  • incandescent13 lm/W5769.2 W
Light reaching the floor
1500 lux
Light you need
75000 lm
Room size
50 ㎡
In pyeong
15.1
In 800-lumen bulbs
94
A month of electricity
112.5 kWh
Extra watts if incandescent
5019 W

Several lamps beat one

The same lumens crammed into one fitting light the spot beneath and leave the corners dark. Splitting them across several 800-lumen lamps softens shadows, and one failure no longer means a dark room.

Nearby cells

Same room, other uses

Same use, other sizes

How to read this

  • The light you need is lux times floor area; the use decides the lux.
  • Watts are only that light divided by the lamp’s efficacy — not a measure of brightness.
  • Bulb counts round up from one 800-lumen lamp.
  • Ceiling height, wall colour and shades are not in this calculation.

Frequently asked questions

Q. How many lumens for a 50 m² operating table?

75000 lumens — 1500 lux times the floor area.

Q. How many watts should the lamp be?

750 W as LED, 1250 W as fluorescent. An incandescent would draw 5769.2 W — 5019 W more.

Q. How many bulbs do I need?

94 at 800 lumens each. Spread them out rather than stacking them in one fitting.

Q. What does it cost to run?

On LED at five hours a day, 112.5 kWh a month.