Motor torque·0.75kW 1200rpm
0.75kW 1200rpm
5.97 N·m
0.609 kgf·m
60 Hz · 6P · 125.66 rad/s

0.75kW 1200rpm motor torque — 5.97 N·m

A 0.75kW 1200rpm motor delivers 5.97 N·m of rated torque. That is 750 W divided by an angular velocity of 125.66 rad/s, the same torque written as 0.609 kgf·m or 4.4 lb·ft. In horsepower, 0.75 kW is 1.02 PS on the metric definition and 1.01 hp on the mechanical one.

Poles and mains frequency fix the speed

The synchronous speed of an induction motor is not a choice: it is 120 × frequency ÷ poles. The same four-pole motor therefore turns at 1800 rpm on 60 Hz and 1500 rpm on 50 Hz — Korea, the United States and eastern Japan run 60 Hz, while Europe, China and India run 50 Hz. Same power, speeds in a 6 : 5 ratio, so the torques land in a 5 : 6 ratio. In service the rotor lags by the slip, which is why the nameplate reads something like 1746 rpm.

Rated output
0.75 kW · 750 W
Synchronous speed
1200 rpm
Mains frequency
60 Hz
Poles
6
Angular velocity
125.66 rad/s
Torque
5.97 N·m
Torque in kgf·m
0.609 kgf·m
Torque in lb·ft
4.4 lb·ft
Metric horsepower (PS)
1.02 PS
Mechanical horsepower (hp)
1.01 hp
Full-load speed
1164 rpm · 6.15 N·m

Through a gearbox

Put a reduction ratio i in the path and the output shaft turns at 1/i of the speed while the torque grows i-fold. Power does not grow — it shrinks by the efficiency η, so the torque is i × η times the input. The figures here assume η = 0.95, typical of a helical gearbox. A worm drive falls to 0.5–0.8 and delivers far less. More torque never means more energy: the same power is simply traded for slower, heavier turning.

  • Gear ratio 3 · 400 rpm17 N·m
  • Gear ratio 5 · 240 rpm28.3 N·m
  • Gear ratio 10 · 120 rpm56.7 N·m
  • Gear ratio 20 · 60 rpm113 N·m

Three-phase current by voltage

For a three-phase induction motor the current is I = P ÷ (√3 × V × cosφ × η). Rated output is what leaves the shaft, so the electrical input is larger by the efficiency, and only the working share of that counts through the power factor. Supply voltage differs by country, so the same motor draws 1.7 times as much at 220 V as at 380 V. The power factor and efficiency used here are representative values by frame size; the nameplate carries the real ones and should be read first.

  • 220 V · cosφ 0.72 · η 0.753.64 A
  • 380 V · cosφ 0.72 · η 0.752.11 A
  • 460 V · cosφ 0.72 · η 0.751.74 A

Nearby cells

Same output, other speeds

Same speed, other outputs

Worth knowing

  • Torque (N·m) is power (W) divided by angular velocity (rad/s), and that velocity is 2π × rpm ÷ 60.
  • The 9550 in T = 9550 × P(kW) ÷ n(rpm) is 60000 ÷ 2π rounded up.
  • At constant power, doubling the speed halves the torque — they are inversely proportional.
  • Metric horsepower (PS) is 735.49875 W and mechanical horsepower (hp) is 745.699872 W: different numbers.

Related tables

Common questions

Q. How much torque does a 0.75kW 1200rpm motor make?

5.97 N·m — 750 W divided by an angular velocity of 125.66 rad/s. The same figure is 0.609 kgf·m or 4.4 lb·ft.

Q. What happens through a 10:1 gearbox?

The speed drops to 120 rpm and the torque rises to 56.7 N·m. It is not a clean 10-fold gain because the gearbox efficiency of 0.95 is applied as well.

Q. How much three-phase current does it draw?

On 60 Hz: 3.64 A at 220 V, 2.11 A at 380 V, 1.74 A at 460 V. This assumes a representative power factor of 0.72 and efficiency of 0.75, so use the nameplate figures when you have them.