RAID capacity·RAID 1 · 15disks
RAID 1 · 15disks
1disks
Capacity efficiency 6.7%

RAID 1 with 15 disks — 1 usable

15 disks in RAID 1 give you 1 disks’ worth, with 14 spent on parity or mirroring. That is 6.7% efficiency, and it always survives 14 failures.

Disks
15
Usable disks
1
Spent on parity or mirror
14
Capacity efficiency
6.7%
Failures always survived
14
Best case
14
Groups
1
Disks per group
15

RAID 1

Every disk holds the same data. It survives down to a single disk, but only one disk’s worth is usable.

TB on the label, TiB on the screen

  • 1 TB × 151 TB · 0.91 TiB
  • 2 TB × 152 TB · 1.82 TiB
  • 4 TB × 154 TB · 3.64 TiB
  • 6 TB × 156 TB · 5.46 TiB
  • 8 TB × 158 TB · 7.28 TiB
  • 10 TB × 1510 TB · 9.09 TiB
  • 12 TB × 1512 TB · 10.91 TiB
  • 14 TB × 1514 TB · 12.73 TiB
  • 16 TB × 1516 TB · 14.55 TiB
  • 18 TB × 1518 TB · 16.37 TiB
  • 20 TB × 1520 TB · 18.19 TiB
  • 22 TB × 1522 TB · 20.01 TiB
  • 24 TB × 1524 TB · 21.83 TiB

One TB on the box is 10¹² bytes, while the operating system counts in units of 2⁴⁰ bytes. The names look alike but the units differ, so the same disk reads about 9% smaller. Nothing went missing — the ruler changed.

Same disk count, other levels

Same level, other disk counts

The rebuild is the dangerous part

When a single-parity array loses a disk, you put a new one in and every remaining disk is read end to end to rebuild it. That is precisely when the survivors work hardest and longest. The bigger and more numerous the disks, the longer the rebuild — days, sometimes — and a second failure during it ends the array. This is why RAID 6 or 10 is preferred over RAID 5 on large arrays.

How to read it

  • Usable = total − parity × groups. Every level is that one line.
  • RAID 5 spends one parity disk in a single group, so n−1; RAID 6 spends two, so n−2.
  • RAID 50 and 60 run several such groups striped together, so the parity is multiplied by the group count.
  • RAID 1 holds one copy on every disk, so one disk’s worth; RAID 10 mirrors in pairs, so half.
  • Groups must be equal in size, so the group count can only be a divisor of the disk count.
  • TB on the box and TiB on the screen are different units — about 9% apart.

RAID is not a backup

RAID protects against exactly one thing: a disk dying. A file deleted by mistake, a file overwritten, ransomware, a failed controller, fire or theft all propagate to every disk at once — a mirror deletes just as faithfully as it writes. A backup is a separate copy on separate hardware, and RAID is not doing that job.

Common questions

Q. How much do 15 disks give in RAID 1?

1 disks’ worth. 14 go to parity or mirroring, for 6.7% efficiency.

Q. How many failures does it survive?

14 always, and up to 14 if they land in the right places.

Q. How many TB with 4 TB disks?

4 TB, which the operating system shows as 3.64 TiB — different units, same bytes.

Q. What is this level?

Every disk holds the same data. It survives down to a single disk, but only one disk’s worth is usable.