RAID capacity·RAID 60 · 25disks
RAID 60 · 25disks
15disks
Capacity efficiency 60%

RAID 60 with 25 disks — 15 usable

25 disks in RAID 60 give you 15 disks’ worth, with 10 spent on parity or mirroring. That is 60% efficiency, and it always survives 2 failures.

Disks
25
Usable disks
15
Spent on parity or mirror
10
Capacity efficiency
60%
Failures always survived
2
Best case
10
Groups
5
Disks per group
5

RAID 60

Several RAID 6 groups striped together. Each group spends two disks on parity.

TB on the label, TiB on the screen

  • 1 TB × 2515 TB · 13.64 TiB
  • 2 TB × 2530 TB · 27.28 TiB
  • 4 TB × 2560 TB · 54.57 TiB
  • 6 TB × 2590 TB · 81.85 TiB
  • 8 TB × 25120 TB · 109.14 TiB
  • 10 TB × 25150 TB · 136.42 TiB
  • 12 TB × 25180 TB · 163.71 TiB
  • 14 TB × 25210 TB · 190.99 TiB
  • 16 TB × 25240 TB · 218.28 TiB
  • 18 TB × 25270 TB · 245.56 TiB
  • 20 TB × 25300 TB · 272.85 TiB
  • 22 TB × 25330 TB · 300.13 TiB
  • 24 TB × 25360 TB · 327.42 TiB

One TB on the box is 10¹² bytes, while the operating system counts in units of 2⁴⁰ bytes. The names look alike but the units differ, so the same disk reads about 9% smaller. Nothing went missing — the ruler changed.

Same disk count, other levels

Same level, other disk counts

The rebuild is the dangerous part

When a single-parity array loses a disk, you put a new one in and every remaining disk is read end to end to rebuild it. That is precisely when the survivors work hardest and longest. The bigger and more numerous the disks, the longer the rebuild — days, sometimes — and a second failure during it ends the array. This is why RAID 6 or 10 is preferred over RAID 5 on large arrays.

How to read it

  • Usable = total − parity × groups. Every level is that one line.
  • RAID 5 spends one parity disk in a single group, so n−1; RAID 6 spends two, so n−2.
  • RAID 50 and 60 run several such groups striped together, so the parity is multiplied by the group count.
  • RAID 1 holds one copy on every disk, so one disk’s worth; RAID 10 mirrors in pairs, so half.
  • Groups must be equal in size, so the group count can only be a divisor of the disk count.
  • TB on the box and TiB on the screen are different units — about 9% apart.

RAID is not a backup

RAID protects against exactly one thing: a disk dying. A file deleted by mistake, a file overwritten, ransomware, a failed controller, fire or theft all propagate to every disk at once — a mirror deletes just as faithfully as it writes. A backup is a separate copy on separate hardware, and RAID is not doing that job.

Common questions

Q. How much do 25 disks give in RAID 60?

15 disks’ worth. 10 go to parity or mirroring, for 60% efficiency.

Q. How many failures does it survive?

2 always, and up to 10 if they land in the right places.

Q. How many TB with 4 TB disks?

60 TB, which the operating system shows as 54.57 TiB — different units, same bytes.

Q. What is this level?

Several RAID 6 groups striped together. Each group spends two disks on parity.