Insulation·graphite EPS 250mm
graphite EPS · 250mm
R 8.06
U 0.121 W/m²·K

graphite EPS, 250 mm — R 8.06

250 mm divided by a conductivity of 0.031 gives an R-value of 8.06. The U-value is 0.121, so a square metre leaks 2.43 W across a 20-degree difference.

Standards it meets

  • passive house 0.15
  • Korean central-region wall 0.17
  • loose standard 0.30
Material
graphite EPS
Thickness
250 mm
Thermal conductivity
0.031 W/m·K
Thermal resistance
8.06 m²·K/W
U-value
0.121 W/m²·K
Heat lost per square metre
2.43 W
As concrete
12.9 m

Thickness for the same performance

This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.

  • vacuum panel56 mm
  • phenolic foam161 mm
  • rigid polyurethane185 mm
  • extruded polystyrene226 mm
  • white EPS290 mm
  • glass wool298 mm
  • mineral wool323 mm
  • cellulose339 mm
  • timber1048 mm
  • plasterboard1452 mm
  • concrete12903 mm

Nearby cells

Same material, other thicknesses

Same thickness, other materials

How to read this

  • Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
  • The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
  • Resistances add across layers, so a whole wall is the sum of its parts.
  • Conductivity varies by product; the values here are typical for the material.

Frequently asked questions

Q. What is the R-value of 250 mm of graphite EPS?

8.06 — 250 mm in metres divided by a conductivity of 0.031.

Q. And the U-value?

0.121. That is 8.23 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 2.43 W across 20 degrees.

Q. How much concrete would match it?

12.9 metres.

Q. Which standards does it meet?

At 0.121 it clears 3 of them.