graphite EPS · 400mm
R 12.9
U 0.076 W/m²·K
graphite EPS, 400 mm — R 12.9
400 mm divided by a conductivity of 0.031 gives an R-value of 12.9. The U-value is 0.076, so a square metre leaks 1.53 W across a 20-degree difference.
Standards it meets
- passive house 0.15
- Korean central-region wall 0.17
- loose standard 0.30
- Material
- graphite EPS
- Thickness
- 400 mm
- Thermal conductivity
- 0.031 W/m·K
- Thermal resistance
- 12.9 m²·K/W
- U-value
- 0.076 W/m²·K
- Heat lost per square metre
- 1.53 W
- As concrete
- 20.65 m
Thickness for the same performance
This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.
- vacuum panel90 mm
- phenolic foam258 mm
- rigid polyurethane297 mm
- extruded polystyrene361 mm
- white EPS465 mm
- glass wool477 mm
- mineral wool516 mm
- cellulose542 mm
- timber1677 mm
- plasterboard2323 mm
- concrete20645 mm
Nearby cells
Same material, other thicknesses
Same thickness, other materials
How to read this
- Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
- The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
- Resistances add across layers, so a whole wall is the sum of its parts.
- Conductivity varies by product; the values here are typical for the material.
Frequently asked questions
Q. What is the R-value of 400 mm of graphite EPS?
12.9 — 400 mm in metres divided by a conductivity of 0.031.
Q. And the U-value?
0.076. That is 13.07 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 1.53 W across 20 degrees.
Q. How much concrete would match it?
20.65 metres.
Q. Which standards does it meet?
At 0.076 it clears 3 of them.