Insulation·graphite EPS 30mm
graphite EPS · 30mm
R 0.97
U 0.879 W/m²·K

graphite EPS, 30 mm — R 0.97

30 mm divided by a conductivity of 0.031 gives an R-value of 0.97. The U-value is 0.879, so a square metre leaks 17.58 W across a 20-degree difference.

Standards it meets

Not up to any of them yet

Material
graphite EPS
Thickness
30 mm
Thermal conductivity
0.031 W/m·K
Thermal resistance
0.97 m²·K/W
U-value
0.879 W/m²·K
Heat lost per square metre
17.58 W
As concrete
1.55 m

Thickness for the same performance

This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.

  • vacuum panel7 mm
  • phenolic foam19 mm
  • rigid polyurethane22 mm
  • extruded polystyrene27 mm
  • white EPS35 mm
  • glass wool36 mm
  • mineral wool39 mm
  • cellulose41 mm
  • timber126 mm
  • plasterboard174 mm
  • concrete1548 mm

Nearby cells

Same material, other thicknesses

Same thickness, other materials

How to read this

  • Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
  • The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
  • Resistances add across layers, so a whole wall is the sum of its parts.
  • Conductivity varies by product; the values here are typical for the material.

Frequently asked questions

Q. What is the R-value of 30 mm of graphite EPS?

0.97 — 30 mm in metres divided by a conductivity of 0.031.

Q. And the U-value?

0.879. That is 1.14 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 17.58 W across 20 degrees.

Q. How much concrete would match it?

1.55 metres.

Q. Which standards does it meet?

At 0.879 it does not clear any of them yet.