Insulation·vacuum panel 150mm
vacuum panel · 150mm
R 21.43
U 0.046 W/m²·K

vacuum panel, 150 mm — R 21.43

150 mm divided by a conductivity of 0.007 gives an R-value of 21.43. The U-value is 0.046, so a square metre leaks 0.93 W across a 20-degree difference.

Standards it meets

  • passive house 0.15
  • Korean central-region wall 0.17
  • loose standard 0.30
Material
vacuum panel
Thickness
150 mm
Thermal conductivity
0.007 W/m·K
Thermal resistance
21.43 m²·K/W
U-value
0.046 W/m²·K
Heat lost per square metre
0.93 W
As concrete
34.29 m

Thickness for the same performance

This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.

  • phenolic foam429 mm
  • rigid polyurethane493 mm
  • extruded polystyrene600 mm
  • graphite EPS664 mm
  • white EPS771 mm
  • glass wool793 mm
  • mineral wool857 mm
  • cellulose900 mm
  • timber2786 mm
  • plasterboard3857 mm
  • concrete34286 mm

Nearby cells

Same material, other thicknesses

Same thickness, other materials

How to read this

  • Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
  • The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
  • Resistances add across layers, so a whole wall is the sum of its parts.
  • Conductivity varies by product; the values here are typical for the material.

Frequently asked questions

Q. What is the R-value of 150 mm of vacuum panel?

21.43 — 150 mm in metres divided by a conductivity of 0.007.

Q. And the U-value?

0.046. That is 21.6 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 0.93 W across 20 degrees.

Q. How much concrete would match it?

34.29 metres.

Q. Which standards does it meet?

At 0.046 it clears 3 of them.