vacuum panel · 200mm
R 28.57
U 0.035 W/m²·K
vacuum panel, 200 mm — R 28.57
200 mm divided by a conductivity of 0.007 gives an R-value of 28.57. The U-value is 0.035, so a square metre leaks 0.7 W across a 20-degree difference.
Standards it meets
- passive house 0.15
- Korean central-region wall 0.17
- loose standard 0.30
- Material
- vacuum panel
- Thickness
- 200 mm
- Thermal conductivity
- 0.007 W/m·K
- Thermal resistance
- 28.57 m²·K/W
- U-value
- 0.035 W/m²·K
- Heat lost per square metre
- 0.7 W
- As concrete
- 45.71 m
Thickness for the same performance
This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.
- phenolic foam571 mm
- rigid polyurethane657 mm
- extruded polystyrene800 mm
- graphite EPS886 mm
- white EPS1029 mm
- glass wool1057 mm
- mineral wool1143 mm
- cellulose1200 mm
- timber3714 mm
- plasterboard5143 mm
- concrete45714 mm
Nearby cells
Same material, other thicknesses
Same thickness, other materials
How to read this
- Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
- The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
- Resistances add across layers, so a whole wall is the sum of its parts.
- Conductivity varies by product; the values here are typical for the material.
Frequently asked questions
Q. What is the R-value of 200 mm of vacuum panel?
28.57 — 200 mm in metres divided by a conductivity of 0.007.
Q. And the U-value?
0.035. That is 28.74 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 0.7 W across 20 degrees.
Q. How much concrete would match it?
45.71 metres.
Q. Which standards does it meet?
At 0.035 it clears 3 of them.