Insulation·plasterboard 200mm
plasterboard · 200mm
R 1.11
U 0.781 W/m²·K

plasterboard, 200 mm — R 1.11

200 mm divided by a conductivity of 0.18 gives an R-value of 1.11. The U-value is 0.781, so a square metre leaks 15.61 W across a 20-degree difference.

Standards it meets

Not up to any of them yet

Material
plasterboard
Thickness
200 mm
Thermal conductivity
0.18 W/m·K
Thermal resistance
1.11 m²·K/W
U-value
0.781 W/m²·K
Heat lost per square metre
15.61 W
As concrete
1.78 m

Thickness for the same performance

This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.

  • vacuum panel8 mm
  • phenolic foam22 mm
  • rigid polyurethane26 mm
  • extruded polystyrene31 mm
  • graphite EPS34 mm
  • white EPS40 mm
  • glass wool41 mm
  • mineral wool44 mm
  • cellulose47 mm
  • timber144 mm
  • concrete1778 mm

Nearby cells

Same material, other thicknesses

Same thickness, other materials

How to read this

  • Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
  • The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
  • Resistances add across layers, so a whole wall is the sum of its parts.
  • Conductivity varies by product; the values here are typical for the material.

Frequently asked questions

Q. What is the R-value of 200 mm of plasterboard?

1.11 — 200 mm in metres divided by a conductivity of 0.18.

Q. And the U-value?

0.781. That is 1.28 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 15.61 W across 20 degrees.

Q. How much concrete would match it?

1.78 metres.

Q. Which standards does it meet?

At 0.781 it does not clear any of them yet.