Insulation·mineral wool 200mm
mineral wool · 200mm
R 5
U 0.193 W/m²·K

mineral wool, 200 mm — R 5

200 mm divided by a conductivity of 0.04 gives an R-value of 5. The U-value is 0.193, so a square metre leaks 3.87 W across a 20-degree difference.

Standards it meets

  • loose standard 0.30
Material
mineral wool
Thickness
200 mm
Thermal conductivity
0.04 W/m·K
Thermal resistance
5 m²·K/W
U-value
0.193 W/m²·K
Heat lost per square metre
3.87 W
As concrete
8 m

Thickness for the same performance

This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.

  • vacuum panel35 mm
  • phenolic foam100 mm
  • rigid polyurethane115 mm
  • extruded polystyrene140 mm
  • graphite EPS155 mm
  • white EPS180 mm
  • glass wool185 mm
  • cellulose210 mm
  • timber650 mm
  • plasterboard900 mm
  • concrete8000 mm

Nearby cells

Same material, other thicknesses

Same thickness, other materials

How to read this

  • Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
  • The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
  • Resistances add across layers, so a whole wall is the sum of its parts.
  • Conductivity varies by product; the values here are typical for the material.

Frequently asked questions

Q. What is the R-value of 200 mm of mineral wool?

5 — 200 mm in metres divided by a conductivity of 0.04.

Q. And the U-value?

0.193. That is 5.17 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 3.87 W across 20 degrees.

Q. How much concrete would match it?

8 metres.

Q. Which standards does it meet?

At 0.193 it clears 1 of them.