glass wool · 200mm
R 5.41
U 0.179 W/m²·K
glass wool, 200 mm — R 5.41
200 mm divided by a conductivity of 0.037 gives an R-value of 5.41. The U-value is 0.179, so a square metre leaks 3.59 W across a 20-degree difference.
Standards it meets
- loose standard 0.30
- Material
- glass wool
- Thickness
- 200 mm
- Thermal conductivity
- 0.037 W/m·K
- Thermal resistance
- 5.41 m²·K/W
- U-value
- 0.179 W/m²·K
- Heat lost per square metre
- 3.59 W
- As concrete
- 8.65 m
Thickness for the same performance
This is the number that shows what insulation is worth. Matching 100 mm of XPS with concrete alone would take 5.7 metres of it. No one builds a wall like that — which is why a concrete building only gets warm once a thin layer of insulation is added.
- vacuum panel38 mm
- phenolic foam108 mm
- rigid polyurethane124 mm
- extruded polystyrene151 mm
- graphite EPS168 mm
- white EPS195 mm
- mineral wool216 mm
- cellulose227 mm
- timber703 mm
- plasterboard973 mm
- concrete8649 mm
Nearby cells
Same material, other thicknesses
Same thickness, other materials
How to read this
- Thermal resistance is the thickness in metres divided by the conductivity. Bigger is better.
- The U-value adds 0.17 of surface resistance and then flips the total. Smaller is better.
- Resistances add across layers, so a whole wall is the sum of its parts.
- Conductivity varies by product; the values here are typical for the material.
Frequently asked questions
Q. What is the R-value of 200 mm of glass wool?
5.41 — 200 mm in metres divided by a conductivity of 0.037.
Q. And the U-value?
0.179. That is 5.58 — the resistance plus 0.17 of surface — turned upside down, and a square metre leaks 3.59 W across 20 degrees.
Q. How much concrete would match it?
8.65 metres.
Q. Which standards does it meet?
At 0.179 it clears 1 of them.